Potential mechanical causes
- Misalignment.
- Worn bearings.
- Rotating part imbalance.
- Loose base.
Potential electrical causes
- Phase imbalance.
- Winding issues.
Correct approach
Measure electrical parameters while simultaneously checking the mechanical installation to avoid incorrectly assuming that every vibration originates from the motor.